1-7
1
1.5
SERIAL INTERFACES (2363)
Model 2363s have their RS-232 and RS-485 signals on an RS-530 compatible
25-pin female connector on the rear panel. The 2363 automatically
responds to the serial port that received the last message.
1.5.1
Baud Rate and Character Format
Baud Rate
Any rate from 300 to 115,200 baud. Parser
selects closest rate to specified rate when non-
standard rate entered. Standard rates are: 300,
600, 1200, 2400, 4800, 7200, 9600, 14400, 19200,
28800, 38400, 57600, 76800, 92160 and 115200
baud.
Format
7 or 8 data bits; odd, even or no parity;
Stop Bits
1 or 2 stop bits
1.5.2 RS-232 Interface
The RS-232 Interface has the following characteristics:
Signals
BA, BB and AB
Mode
Full Duplex with or without echo
Flow control
none
Control-E
Sets echo on
Control-F
Sets echo off
1.5.3 RS-485 Interface
The RS-485 Interface may be used in 2-wire, RS-422 or RS-485 point-to-
point or network applications and has the following characteristics:
Signals
Tx/Rx+ and Tx/Rx- signal pairs
Mode
Half Duplex
Termination
220 ohm load resistor with 1 kohm pullup and
pulldown resistors
Prompts
CR-LF-prompt for terminal control
LF-prompt for computer control
Protocols
None, Addressed and Packet Protocol
Addresses
16