2
SETTING UP THE IP1000C SYSTEM
2-27
3. After selecting the “Port Type” item to “Controller 1” in the [Bridge Connection Point] field, enter the IP
address of the VE-PG3. (Example: 192.168.0.2)
Enter the Connection Port Number. (Example: 21502)
Enter the “My Station Port Number” same as the Connection Port number of the Digital Transceiver 1
(D-TRX1). (Example: 21500)
Select the Voice Cording. (Example: AMBE+2)
[Bridge Connection] (menu) > [Bridge Connection] (screen) > [Bridge Connection Point] (field)
L
Make sure the using port number for connection do not duplicate with another connection.
About the VE-PG3 settings (Bridge mode)
2. After selecting the “Port Type” item to “Digital Transceiver 1 (D-TRX1)” in the [Bridge Connection Point]
field, enter the IP address of the VE-PG3. (Example: 192.168.0.2)
Enter the Connection Port Number. (Example: 21500)
Enter the “My Station Port Number” same as the Connection Port number of the Controller 1. (Example: 21502)
Select the Voice Cording. (Example: AMBE+2)
[Bridge Connection] (menu) > [Bridge Connection] (screen) > [Bridge Connection Point] (field)
L
Make sure the using port number for connection do not duplicate with another connection.
IP100H
Controller connection
Additional Controller Link
IP100H makes a Group Call with the Additional Controller Link (VE-PG3)
192.168.0.3
(Area B)
192.168.0.2
192.168.0.11
(Area A)
Port number (D-TRX1): 21502
Port number (Controller 1): 21500
Sales31
00031
Sales32
00032
Sales group3
00301
VE-PG3
IP1000C
(RoIP Gateway)
[D-TRX1]
Transceiver
CT-24
[USB]
Repeater A
P0
P1
P2
P3
P4
5. Additional controller link with VE-PG3