4
ABOUT THE SETTING SCREEN
4-95
8. [Transceiver Settings] Menu
[Transceiver Settings]–[Transceiver Settings]
■
Transceiver Settings [IP110H]
63
Man Down �������
Select whether or not to use the Man Down function. (Default: Disable)
If the Man Down function is activated, the Emergency function is
automatically turned ON after the set period of time has passed with the
transceiver leaning past the preset angle.
Example:
ON Timer: 10 seconds
Reminder Timer: 10 seconds
Angle: 45 degrees
10 sec.
10 sec.
Angle
Time
ON Timer
Reminder
Timer
Emergency
call
Past 45 degrees
Reminder beep
sounds.
The Emergency
function turns ON.
63
64
65
66
67
68
69
70
71
72
(This is only an example.)