Maint
08-0380
8.3.15 Replacing Reverse assembly
(1) Remove the Top Cover, Main Cover (L) / (R), and Side Cover (L) / (R). See
“8.1.1 How to remove or attach
the covers”
.
(2) Remove the Input Tray. See
“8.3.6 Replacing Input Tray”
.
(3) Remove the Eject Guide assembly. See
“8.1.2 How to remove or attach the guides”
.
(4) Remove the Reverse Roller assembly with lifting it up. See
“8.2.2 Replacing Reverse Roller assembly
.
(5) Loosing the washer faced head screws (305) fixing the Reveres Spring Support, and lower the Reverse Spring
Support.
(6) Remove the Reverse Spring.
(7) Remove 2 bind-head screws (SB306N) fixing the Reverse assembly.
(8) Remove the Belt.
Reverse
assembly
bind-head screws (SB306N)
x2
Reverse Spring
washer faced head screws
(305)
x2
Reverse Spring Support
Belt
Necessary Tools: Phillips Screwdriver (No.2)