Maint 00-0120
4 NOTICE
•
If the glass part is borken, chipped, or cracked, replace the CIS Unit assembly (Front / Back).
•
Absolute ethanol is usable for cleaning
•
When you clean parts, do it scrupulously.
(Maint 03-0020)
•
Do not make scratches on the rollers. If you do, conveyance error may result.
(Maint 03-0040)
•
When you install an ink cartridge, make sure the direction is correct.
•
If the direction is not correct, the nozzle unit may break, and printing may not be possible.
(Maint 03-0060)
•
When you clean, use nonwoven fabric or other material that does not generate much dust.
•
If fabric or other material remains on the Nozzle Unit, that causes deguration of the print quarity
(Maint 03-0070)
•
Do not clean the SS Sensor assembly with excessive force. If you do, position detection may be
affected, and malfunction may result.
(Maint 03-0130)
•
After the test, make sure you set the setting switch back to "0".
•
Do not set the setting switch to a position other than "0" or "8".
(Maint 05-0010)
•
If you update the setting in the Start mode [2] or [3], after the setting is stored, the device will restart.
Do not turn off the device during this period. After the device restarts, wait until the device goes into
the ready mode.
(Maint 07-0040)
•
Check if the new version is correct to ensure the correct update.
•
If you download a file in Start mode [2], after the downloaded program is programmed, the device
will restart.
•
Do not turn off the device even when a message is displayed to indicate download is finished.
•
After the device restarts, wait until the device goes into the standby mode.
(Maint 07-0080)
•
When you update the setting, check if the new setting is correct to ensure the correct update.
•
If you change the options in the Start mode [2], after the option settings are stored, the device will
restart. Do not turn off the device until the device goes into the standby mode.
•
Confirm that the model name, options and the special order options are correct.
•
Normally, the device information is stored before the replacement using the procedure described in
"
7.6 Load / Store Device Unique Information
", and load the stored device information back to the new
Main PCB assembly (CPS878) after the replacement. This function is used to directly change the
settings if for some reason, loading and storing the settings is not possible when you replace the Main
PCB assembly (CPS878).
(Maint 07-0110)
•
If you load a file in Start mode [2], after the loaded file is programmed, the device will restart. Do not
turn off the device even when a screen is displayed to indicate download is finished. After the device
restarts, wait until the device goes into the standby mode.
(Maint 07-0150)