5.
From
the
rear
of
the
server,
remove
the
two
screws
at
each
side
of
the
power
supply
cage.
2
1
6.
Gently
pull
the
power
supply
cage
from
the
server,
making
sure
the
cables
do
not
snag
on
the
chassis
or
system
board.
Note:
You
might
need
to
insert
the
blade
of
a
screwdriver
behind
one
corner
of
the
power
supply
cage
to
begin
moving
it.
Center-fan
and
adapter-support
bracket
Note:
v
Read
“Installation
guidelines”
on
page
11.
v
Read
Appendix
B,
“Safety
information,”
on
page
153.
v
Read
“Handling
static-sensitive
devices”
on
page
12.
When
working
with
some
options,
you
must
first
remove
the
center-fan
and
or
adapter-support
bracket
to
access
certain
components
or
connectors
on
the
system
board.
Note:
The
adapter-support
bracket
is
attached
to
the
center-fan
bracket.
Both
brackets
can
be
removed
and
installed
together
as
a
single
unit
or
individually.
See
“Center-fan
support
bracket
(dual
fan
guide)”
on
page
69
or
“Adapter-support
bracket”
on
page
70
for
instructions
on
how
to
remove
these
support
brackets
separately.
Chapter
4.
Service
replaceable
units
67
Summary of Contents for xSeries 236 8841
Page 1: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 96: ...86 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 152: ...142 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 160: ...150 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 173: ...Appendix B Safety information 163...
Page 174: ...164 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ...Appendix B Safety information 165...
Page 176: ...166 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 177: ...Appendix B Safety information 167...
Page 178: ...168 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 179: ...Appendix B Safety information 169...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Safety information 181...
Page 192: ...182 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 196: ...186 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 208: ...198 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ......
Page 210: ...Part Number 25K8114 1P P N 25K8114...