Dimensions
and
weight:
Height
Width
Depth
Approximate
Maximum
Weight
43
mm
(1.7
in.)
440
mm
(17.3
in.)
660
mm
(26
in.)
12.7
kg
(28
lb.)
Additional
space
requirements:
Location
Additional
space
required
Reason
Left-
and
right-hand
sides
50
mm
(2
in.)
Cooling
air
flow
Back
100
mm
(4
in.)
minimum
Cable
exit
AC
input-voltage
requirements:
Power
Supply
Assembly
Type
Voltage
Frequency
220
V
88
to
264
V
ac
47
to
63
Hz
Environment:
Environment
Temperature
Altitude
Relative
humidity
Maximum
wet
bulb
temperature
Operating
10°C
to
35°C
(50°F
to
95°F)
0
to
914
m
(0
to
2998
ft.)
8%
to
80%
noncondensing
23°C
(74°F
)
10°C
to
32°C
(50°F
to
88°F)
914
to
2133
m
(2998
to
6988
ft.)
8%
to
80%
noncondensing
23°C
(74°F
)
Powered
off
10°C
to
43°C
(50°F
to
110°F)
–
8%
to
80%
noncondensing
27°C
(81°F
)
Storing
1°C
to
60°C
(34°F
to
140°F)
0
to
2133
m
(0
to
6988
ft.)
5%
to
80%
noncondensing
29°C
(84°F)
Shipping
−20°C
to
60°C
(−4°F
to
140°F)
0
to
10668
m
(0
to
34991
ft.)
5%
to
100%
condensing,
but
no
precipitation
29°C
(84°F)
Heat
output
(maximum):
350
watts
(1195
Btu
per
hour)
©
Copyright
IBM
Corp.
2003,
2004
47
Summary of Contents for TotalStorage
Page 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 2: ......
Page 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 22: ...xx Installation Guide...
Page 36: ...14 Installation Guide...
Page 58: ...36 Installation Guide...
Page 74: ...52 Installation Guide...
Page 80: ...58 Installation Guide...
Page 84: ...62 Installation Guide...
Page 89: ......
Page 90: ...Part Number 64P8120 Printed in USA SC26 7541 02 1P P N 64P8120...
Page 91: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 1 2 0...