electrical
input
power
source
(if
possible)
to
reduce
the
chance
of
input
power
failure
at
both
uninterruptible
power
supplies.
The
SAN
Volume
Controller
software
determines
whether
the
input
voltage
to
the
uninterruptible
power
supply
is
within
range
and
sets
an
appropriate
voltage
alarm
range
on
the
uninterruptible
power
supply.
The
software
continues
to
re-check
the
input
voltage
every
few
minutes;
if
it
changes
substantially
but
remains
within
the
permitted
range,
the
alarm
limits
are
readjusted.
Prerequisites:
Before
you
begin
this
task,
refer
to
the
customer’s
cable
connection
table
in
the
to
identify
the
uninterruptible
power
supply
to
which
this
SAN
Volume
Controller
is
to
be
connected.
Steps:
Perform
the
following
steps
to
connect
the
SAN
Volume
Controller
to
the
uninterruptible
power
supply.
1.
At
the
back
of
the
SAN
Volume
Controller,
plug
a
power
cable
into
the
socket
1
(see
2.
Plug
the
serial
cable
of
the
power
cable
assembly
into
the
serial
socket
2
.
3.
DANGER
You
have
already
switched
on
the
uninterruptible
power
supply.
The
output
sockets
of
the
uninterruptible
power
supply
are
live.
Plug
the
free
end
of
the
SAN
Volume
Controller
power
cable
into
any
vacant
output
socket
3
on
the
uninterruptible
power
supply.
2
1
3
4
Figure
33.
Connecting
the
SAN
Volume
Controller
power
cable
to
the
uninterruptible
power
supply
Chapter
4.
Installing
the
uninterruptible
power
supply,
the
master
console,
and
the
SAN
Volume
Controller
31
Summary of Contents for TotalStorage
Page 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 2: ......
Page 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 22: ...xx Installation Guide...
Page 36: ...14 Installation Guide...
Page 58: ...36 Installation Guide...
Page 74: ...52 Installation Guide...
Page 80: ...58 Installation Guide...
Page 84: ...62 Installation Guide...
Page 89: ......
Page 90: ...Part Number 64P8120 Printed in USA SC26 7541 02 1P P N 64P8120...
Page 91: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 1 2 0...