[HIL-1630], 449, SLOT 1 CHASSIS, INFO, chassis1, Auto-configuring
system airflow direction to Non-portside Intake
If airflow direction for power supply and fan assemblies does not match, WWN cards will not
automatically reconfigure and the fan or power supply assembly with mismatched airflow will fault. In
this case, you must replace fan or power supply assemblies to achieve matching airflow direction for all,
and then reboot the system.
The following procedure is provided if you need to manually synchronize airflow direction on WWN
cards with airflow direction of installed fan and power supply assemblies.
Note:
Changing chassis airflow is only supported to synchronize established airflow direction of installed
fan and power supply assemblies with airflow direction configured on WWN cards. Changing airflow
direction from NPI to NPE or NPE to NPI is not supported in a customer environment.
Procedure
1.
Enter
chassisShow
to display airflow direction programmed in WWN cards and airflow direction of
installed fan and power supply FRUs. Airflow direction of fans and power supplies displays as "Fan
Direction" under each fan or power supply unit. System airflow direction displays as "System
Airflow" under the WWN card unit. The following example shows mismatch of system airflow and
airflow direction in installed fan and power supply as the WWN units should indicate "Non-portside
Intake."
POWER SUPPLY
Unit: 1
Power Source:
AC
Fan Direction:
Non-portside Intake
...
FAN
Unit: 2
Fan Direction:
Non-portside Intake
...
WWN
Unit: 1
System AirFlow:
Non-portside Exhaust
...
WWN
Unit: 2
System AirFlow:
Non-portside Exhaust
2.
To reconfigure airflow direction on installed WWN cards, enter
wwnrecover
.
sw0:admin> wwnrecover
WWN 1 and/or WWN 2 system airflow direction mismatches with the
installed fan FRU’s airflow direction.
WWN Non-Critical Seeprom Problem Details
WWN 1 system airflow direction mismatches with installed Fan FRU’s
airflow direction!!!!
WWN 2 system airflow direction mismatches with installed Fan FRU’s
airflow direction!!!!
Recovery Options
0. Exit
1. Copy Airflow direction from Fan FRU to both WWN cards
3.
Enter 1 when prompted for a recover option to copy airflow direction from the fan to both WWN
cards.
Enter Selection > 1
WWN Airflow direction recovery complete.
Please reboot the system.
4.
Reboot the system.
WWN Cards
159
Summary of Contents for SAN256B-6
Page 6: ...vi SAN256B 6 Installation Service and User Guide...
Page 10: ...x SAN256B 6 Installation Service and User Guide...
Page 22: ...xxii SAN256B 6 Installation Service and User Guide...
Page 24: ...xxiv SAN256B 6 Installation Service and User Guide...
Page 34: ...6 SAN256B 6 Installation Service and User Guide...
Page 72: ...44 SAN256B 6 Installation Service and User Guide...
Page 92: ...64 SAN256B 6 Installation Service and User Guide...
Page 108: ...80 SAN256B 6 Installation Service and User Guide...
Page 152: ...124 SAN256B 6 Installation Service and User Guide...
Page 162: ...134 SAN256B 6 Installation Service and User Guide...
Page 198: ...170 SAN256B 6 Installation Service and User Guide...
Page 206: ...178 SAN256B 6 Installation Service and User Guide...
Page 210: ...182 SAN256B 6 Installation Service and User Guide...
Page 214: ...186 SAN256B 6 Installation Service and User Guide...
Page 218: ...190 SAN256B 6 Installation Service and User Guide...
Page 258: ...230 SAN256B 6 Installation Service and User Guide...
Page 278: ...250 SAN256B 6 Installation Service and User Guide...
Page 286: ...258 SAN256B 6 Installation Service and User Guide...
Page 289: ...WWN card power down replacement 156 Index 261...
Page 290: ...262 SAN256B 6 Installation Service and User Guide...
Page 291: ......
Page 292: ...IBM Part Number 01JC333 Printed in USA SC27 8967 03 1P P N 01JC333...