Installation guidelines
Before you install the support rails for the SAN Volume Controller 2145-CG8 node,
review the following guidelines:
Before you begin
v
Do not install a unit in a rack where the internal-rack ambient temperature
exceeds the lowest manufacturer-recommended ambient temperature for all of
your rack-mounted devices.
v
Do not install a unit in a rack where the air flow is compromised. Ensure that
air flow is not blocked or reduced on any side, front, or back of a unit used for
air flow through the unit.
v
Ensure that the equipment is connected properly to the supply circuit so that the
circuits do not overload and compromise the supply wiring or overcurrrent
protection.
v
Plan the device installation by starting at the bottom of the rack cabinet to
ensure that the rack is stable and cannot tip over.
v
Install the heaviest device in the bottom of the rack cabinet.
v
Do not install a SAN Volume Controller node directly above the pull-out
monitor and keyboard of the IBM System Storage Productivity Center (SSPC)
server. The front panel of the node protrudes beyond the front of the rack and
overlaps part of the monitor, which prevents you from opening it.
Installing the support rails for the SAN Volume Controller
2145-CG8
You must install the support rails that hold the SAN Volume Controller 2145-CG8
node.
Before you begin
Figure 20 shows the items that you need to install the SAN Volume Controller
2145-CG8 node in a rack.
Cable management arm kit
Friction rail kit
7
5
6
3
4
1
2
Figure 20. SAN Volume Controller 2145-CG8 cable-management arm, support rails, and associated parts
26
SAN Volume Controller: Model 2145-CG8 Hardware Installation Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 109: ......
Page 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...