uninterruptible power-supply units that are powering an I/O group to different,
independent electrical power sources. If a single power source fails, the SAN
Volume Controller system can then continue to operate with reduced
performance.
v
When connecting to the 2145 UPS-1U, use only the power cable assembly, part
number 31P1294, that was supplied with the node. Power cable assemblies that
were supplied with previous SAN Volume Controller models do not work with
the 2145-CG8 model because there are two power cables in the bundle for the
2145-CG8 model. The correct part is differentiated by the blue tape that binds
the cables together.
Before you begin this task, see the completed customer's cable-connection table,
which is described in the
IBM System Storage SAN Volume Controller Planning Guide
and can be downloaded from the www.ibm.com/storage/support/2145.
Use the information in this table to identify the 2145 UPS-1U unit to which this
node is to be connected.
Perform the following steps to connect the SAN Volume Controller to the 2145
UPS-1U:
Procedure
1.
At the back of the SAN Volume Controller 2145-CG8 node, plug the power
cables of the combined power and serial cable assembly into the power
connector
2
, as shown in Figure 32.
1
Fibre Channel ports
2
Power connector
3
Serial connector
4
Ethernet ports
5
Main-power connector
svc00540
4
7
3
1
2
6
5
Figure 32. Connecting the SAN Volume Controller power cable to the 2145 UPS-1U
36
SAN Volume Controller: Model 2145-CG8 Hardware Installation Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 109: ......
Page 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...