Chapter 1. SAN Volume Controller overview
The SAN Volume Controller combines software and hardware into a
comprehensive, modular appliance that uses symmetric virtualization.
Symmetric virtualization is achieved by creating a pool of managed disks (MDisks)
from the attached storage systems. Those storage systems are then mapped to a set
of volumes for use by attached host systems. System administrators can view and
access a common pool of storage on the storage area network (SAN). This
functionality helps administrators to use storage resources more efficiently and
provides a common base for advanced functions.
Each SAN Volume Controller node is an individual server in a SAN Volume
Controller clustered system on which the SAN Volume Controller software runs.
The nodes are always installed in pairs, with a minimum of one and a maximum
of four pairs of nodes constituting a
system
. Each pair of nodes is known as an
I/O
group
. All I/O operations that are managed by the nodes in an I/O group are
cached on both nodes.
SAN Volume Controller operating environment
To use SAN Volume Controller, you must meet the minimum hardware and
software requirements and ensure that other operating environment criteria are
met.
Minimum requirements
You must set up your SAN Volume Controller operating environment according to
the following requirements:
v
Minimum of one pair of SAN Volume Controller nodes
v
Minimum of two uninterruptible power supply units
v
One optional IBM System Storage Productivity Center per SAN installation for
configuration
SAN Volume Controller 2145-CG8 node features
The SAN Volume Controller 2145-CG8 node has the following features:
v
A 19-inch rack-mounted enclosure
v
One 4-port 8 Gbps Fibre Channel adapter
v
One 2-port 10 Gbps Fibre Channel over Ethernet converged network adapter
v
24 GB memory
v
Fibre Channel over Ethernet host attachment (need to add only one)
v
One quad-core processor
v
Dual, redundant power supplies
v
Supports up to four optional solid-state drives (SSDs)
v
iSCSI host attachment (1 Gbps Ethernet and optional 10 Gbps Ethernet)
v
Supports optional IBM Real-time Compression
© Copyright IBM Corp. 2012
1
3
3
Summary of Contents for SAN Volume Controller 2145-CG8
Page 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Page 109: ......
Page 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...