Use ipssend format to restart the format of the physical drive. The syntax is:
ipssend format
controller channel sid
where:
•
controller is the ServeRAID controller number (1–12)
•
channel is the channel number for the device (1, 2, or 3)
•
sid is the SCSI ID for the device (0–15)
After the format is complete, the ServeRAID controller will be able to recognize
the drive again.
Recovering from a failure in a failover-environment
In a failover environment, when the ServeRAID device driver is unable to send a
command to the primary controller and the primary controller does not respond to a
reset command, the device driver attempts to failover to the secondary controller.
Note:
Loose cables or defective physical drives will not cause a failover to occur.
Replacing a non-hot-plug controller in a failover pair
If a failed controller is not in a hot-plug PCI slot, do the following to replace it:
1.
Shutdown the server.
2.
Replace the failed controller.
3.
Reconfigure the new controller.
Notes:
1.Be sure the firmware level of the new controller is the same as the controller you are
replacing. Be sure to use the same controller name, partner name, and SCSI
initiator ID for the controller you are replacing.
2.For detailed instructions, refer to the Hardware Maintenance Manual for the
ServeRAID controller being serviced.
If the failed controller is in a hot-plug slot, refer to the documentation that comes with
the server for instructions for replacing the controller.
Diagnostic programs and error messages
The server diagnostic programs are stored in upgradable read-only memory (ROM)
on the system board. These programs are the primary method of testing the major
components of the server.
Diagnostic error messages indicate that a problem exists; they are not intended to be
used to identify a failing part. Troubleshooting and servicing of complex problems
that are indicated by error messages should be performed by trained service
personnel.
Sometimes the first error to occur causes additional errors. In this case, the server
displays more than one error message. Always follow the suggested action
instructions for the first error message that appears.
The following sections contain the error codes that might appear in the detailed test
log and summary log when running the diagnostic programs.
The error code format is as follows:
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......