222
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
035-XXX-SNN
(Check System Error
Log before replacing a FRU. S =
number of failing PCI slot; NN = SCSI ID
of failing fixed disk.)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter
initialization failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain the
basic and extended configuration status and refer to the ServeRAID
Hardware Maintenance Manual for more information.
2.
Cable
3.
SCSI Backplane
4.
Adapter
075-XXX-000
(Failed Power Supply
test)
1.
Power Supply
089-XXX-001
(Failed Microprocessor
test)
1.
VRM for Microprocessor 1
2.
Microprocessor
089-XXX-002
(Failed
Optional Microprocessor test)
1.
VRM for Optional Microprocessor 2
2.
Optional Microprocessor
089-XXX-003
(Failed Optional
Microprocessor test)
1.
VRM for Optional Microprocessor 3
2.
Optional Microprocessor
089-XXX-004
(Failed Optional
Microprocessor test)
1.
VRM for Optional Microprocessor 4
2.
Optional Microprocessor
165-XXX-000
(Failed Service
Processor test)
1.
Check error log for any I2C messages
(see “I2C bus fault messages”
on page 239).
2.
Remove ac power from system for 20 seconds, then rerun service
processor test. If problem persists, proceed to step 3..
3.
I/O Legacy Board. Before replacing the I/O Legacy Board, ensure that
I/O Legacy Board jumper J28 is not installed (the default) when the
error occurs.
180-XXX-000
(Diagnostics LED failure)
1.
Run Diagnostic LED test for the failing LED.
180-XXX-001
(Failed information LED
panel test)
1.
Information LED Panel
2.
Diagnostic LED Panel
3.
I/O Legacy Board
180-XXX-002
(Failed Diagnostics LED
Panel test)
1.
Diagnostics LED Panel
2.
I/O Legacy Board
180-XXX-003
(Failed System Board
LED test)
1.
System Board
180-XXX-004
(Failed Processor
Board LED test)
1.
Processor/PCI Board
2.
I/O Legacy Board
180-XXX-005
(Failed SCSI
Backplane LED test)
1.
SCSI Backplane
2.
SCSI Backplane Cable
3.
I/O Legacy Board
180-XXX-006
(Memory Board LED test)
1.
Memory Board
2.
Processor/PCI Board
3.
I/O Legacy Board
Error Code/Symptom
FRU/Action
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......