224
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
217-XXX-005
(Failed BIOS Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array.
1.
Fixed Disk 6
217-XXX-006
(Failed BIOS Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array.
1.
Fixed Disk 7
217-XXX-007
(Failed BIOS Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array.
1.
Fixed Disk 8
217-XXX-008
(Failed BIOS Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array.
1.
Fixed Disk 9
217-XXX-009
(Failed BIOS Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array.
1.
Fixed Disk 10
264-XXX-0NN
(NN = SCSI ID
of failing Tape Drive)
1.
Tape Cartridge, if user executed the Read/Write Tape Drive test (XXX
= 256)
2.
SCSI or power cable connected to the tape drive with SCSI ID NN
3.
Tape drive with SCSI ID NN – refer to Help and Service Information
appendix of tape drive’s User Guide.
4.
I/O Legacy Board or SCSI Controller – run SCSI Controller diagnostic
to determine of SCSI bus is functioning properly.
264-XXX-999
(Errors on multiple
tape drives, see error text for more info)
1.
See error messages/text in the PC Doctor error log for detailed
information on each individual tape drive error.
301-XXX-000
(Failed Keyboard test)
1.
Keyboard
405-XXX-000
(Failed Ethernet test
on controller on the I/O Legacy Board)
1.
Verify that Ethernet is not disabled in BIOS.
2.
I/O Legacy Board
405-XXX-00N
(Failed Ethernet test on
adapter in PCI slot N)
Note:
Insure modem is present and
attached to server.
1.
Adapter in PCI slot N.
2.
I/O Legacy Board
415-XXX-000
(Failed Modem
test)
1.
Cable
2.
Modem
3.
I/O Legacy Board
Error Code/Symptom
FRU/Action
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......