
Installing and configuring ServeRAID controllers
171
Attention:
1.
When you issue this function, all data on the disk will be lost.
2.
After a format function is issued, do not stop it. If a format
process is stopped for any reason, the hard disk that was being
formatted will not respond to any functions except the format
function. Thus, the ServeRAID controller will not be able to
recognize functions anymore. To recover the drive, refer to
“Recovering from an incomplete format of a physical drive” on
page 185.
Supported operating system: DOS
Command: ipssend format controller channel sid
where:
•
controller is the ServeRAID controller number (1–12)
•
channel is the channel number for the device (1, 2, 3, or 4)
•
sid is the SCSI ID for the device (0–15)
getevent
Use
the
getevent
function to display information about various
unexpected events. IBM uses the soft and hard event logs for
development and debugging purposes only. The device event log
contains event counters for each attached physical device. These
counters include:
•
Parity: An unexpected event occurred while data was being
transferred on the SCSI bus. This usually indicates a problem
with the SCSI cable, connectors, or terminators.
•
Soft: A SCSI device detected a check-condition event.
•
Hard: The SCSI controller detected an unexpected event. The
controller is the most likely cause.
•
Misc: The ServeRAID controller detected an event that was most
likely caused by the device.
The device event log also provides Predictive Failure Analysis (PFA)
alerts, which indicate that the device has signaled the ServeRAID
controller that it might fail in the near future.
Supported operating systems: Windows NT, Windows 2000, OS/2,
NetWare, Linux, OpenServer, UnixWare, and DOS
Command: ipssend getevent controller options
where:
•
controller is the ServeRAID controller number (1–12)
•
options is the designated event log:
— DEVICE for the device event log
— SOFT for the ServeRAID controller soft event log
— HARD for the ServeRAID controller hard event log
selftest
The
selftest
function is used to direct a controller or a device to
perform its self-test.
Supported operating systems: DOS
Command: ipssend selftest controller options
where:
•
controller is the ServeRAID controller number (1–12)
•
options is the designated self-test:
— AD for the ServeRAID controller self-test
— PD channel sid for the device self-test
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......