
188
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
2.
In ServeRAID Manager select the system with Defunct (DDD) drives.
3.
Right click on the system and choose “Save printable configuration and event
logs.” These logs are saved into the installation directory of ServeRAID Manager,
usually
Program Files\RAIDMAN
. The log files are saved as
RAIDX.log
where
X
is
the controller number.
4.
Open the correct log for the controller with Defunct Drives and find the heading
“ServeRAID Defunct (DDD) event log.”
5.
Mark hard disk drive online in order, starting from the bottom of this log.
6.
Rebuild the last drive.
When the operating system is not accessible, to determine the correct order to
software replace, follow the following steps:
1.
Boot to the ServeRAID options CD.
2.
Right click on the local system.
3.
Insert diskette in drive and select “Save printable configuration and event logs.”
4.
Take logs to another system and view. The log files are saved as
RAIDX.log
where
X
is the controller number.
5.
Open the correct log for the controller with Defunct Drives and find the heading
“ServeRAID Defunct (DDD) event log.”
6.
Mark hard disk drive online in order, starting from the bottom of this log.
7.
Rebuild the last drive.
Using and understanding the ServeRAID Monitor Log
The ability to read the ServeRAID log, generated by ServeRAID monitor, is a most
important part of recovering an array when one or more drives are marked Defunct
(DDD). From the ServeRAID log, you can determine in what order drives went
Defunct (DDD), and, if multiple drives are Defunct (DDD), which one is the
“inconsistent” or “out-of-synch” drive. The ServeRAID log is created by running
either ServeRAID monitor or Netfinity Manager. ServeRAID monitor is available
from the IBM web site:
http://www.ibm.com/pc/files.html
Search on “ServeRAID.”
Netfinity Manager is part of ServerGuide, which is shipped with every IBM server.
The following is an excerpt from a ServeRAID log created by ServeRAID monitor:
The original configuration was:
Table 21. Sample ServeRAID log.
RAID log
09/12/97 09:33:36 INF003:A1C-B -- synchronization started
09/12/97 09:40:22 INF004:A1C-B -- synchronization completed
09/12/97 09:41:43 CRT001:A1C3B03 -- dead drive detected
09/12/97 09:42:13 INF001:A1C-B -- rebuild started
09/12/97 09:52:11 INF002:A1C-B -- rebuild completed
09/12/97 09:55:24 CRT001:A1C3B04 -- dead drive detected
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......