Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
Configured drives are not in the configured location.
Explanation:
When the ServeRAID controller detects that a previously configured drive is present, but the drive is in a
new location, the following message appears:
x online drive has been rearranged
where x is the number of drives that have been rearranged. Examples of possible messages are:
Online Drive on
Channel 3 SCSI ID 4 moved to Channel 3 SCSI ID 3
Online Drive on Channel 3 SCSI ID 3 moved to Channel 3 SCSI ID 4
Action:
Press one of the following keys: F2 – Detailed description. Press this key for a detailed description of the
problem, such as the example messages above. F4 – Retry. Press this key after correcting a problem. For example, press
F4 after you move the physical drive to its previously assigned location. F5 – Change the configuration and set the drive
to defunct. Press this key to accept the new state that the ServeRAID controller will assign to the drive. For example,
the ServeRAID controller will assign the drive a state of defunct or empty.
Note:
A physical drive in the defunct state does not necessarily mean that you need to replace the drive. Before you
replace the drive, ensure that:
1.
All cables are connected properly to the backplane and to the physical drive. Also, ensure that all cables
inside the server are connected properly.
2.
The hot-swap drive trays are seated properly in the drive bay.
3.
If you have not already attempted to rebuild the drive, try rebuilding it. See “Rebuilding a defunct drive”
on page 22 for more information.
After you perform these steps, if the physical drive does not function properly, replace the drive. F6 – Change the
configuration and accept the rearrangement. Press this key to modify the configuration to match the current drive
location. You might remove the hot-swap drives from the server for security or maintenance reasons. If you replace
the drives but install them in different drive bays, you can press F6 to accept the new locations, and the ServeRAID
controller will update the configuration. F10 – Continue startup without changing the configuration. Press this key to
continue without change to the configuration.
Controller is not responding to commands. No logical drives are installed.
Explanation:
The ServeRAID controller is not operational.
Action:
Run the IBM ServeRAID Support CD and reseat the adapter. If the problem persists, replace the adapter.
Error: Cannot disable this controller BIOS.
Explanation:
The ServeRAID controller was unable to prevent an extra copy of its BIOS code from being stored on the
server. This condition occurs when the server contains multiple ServeRAID controllers.
Action:
This is an information message. No action is required.
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......