232
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
ServeRAID POST (ISPR) error codes
The ISPR (Interrupt Status Port Register), BCS (Basic Configuration Status), and ECS
(Extended Configuration Status) codes identify the controller state.
Note:
Do not replace a system board containing a ServeRAID adapter unless such a
replacement is a specifically recommended Action.
ServeRAID POST (ISPR) error procedures
The ISPR Error Procedures list errors, symptoms, and the possible causes. The most
probable cause is listed first. Use these procedures to help you solve ServeRAID
problems when servicing the computer.
EF10
(Default ISPR)
1.
No ISPR Error Present.
1XXX
(Microcode Checksum Error)
1.
Replace the ServeRAID controller.
2XXX thru 5XXX
(Code DRAM Error)
1.
Install two download jumpers parallel to the PCI slots. For jumper locations, see
“Processor board component locations” on page 55.
01298003
(No update data for
processor 3)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 3
01298004
(No update data for
processor 4)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 4
01298101
(Bad update data for
processor 1)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 1
01298102
(Bad update data for
processor 2)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 2
01298103
(Bad update data for
processor 3)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 3
01298104
(Bad update data for
processor 4)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 4
I9990301
(Fixed boot sector error)
1.
Hard Disk Drive
2.
If RAID system, refer to the ServeRAID Hardware Maintenance
Manual for more information.
3.
SCSI Backplane
4.
Cable
5.
I/O Legacy Board
I9990305
(Fixed boot sector error, no
operating system installed)
1.
Install operating system to hard disk drive.
I9990650
(AC power has been
restored)
1.
Check cable
2.
Check for interruption of power supply
3.
Power Cable
Error Code/Symptom
FRU/Action
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......