Power Consumption
297
Interfaces
Cables
A power line cord is provided with the printer, but no data cables. The
following provides data cable requirements and ordering information.
ASCII Serial/Parallel: The 6400 printer is connected to personal computers
and controllers via industry standard EIA-232-E and PC-parallel printer
cables. For Dataproducts interfaces, you will need to obtain a Dataproducts
cable. Contact your IBM service representative to order the following:
•
EIA-232-E Cable
•
PC-Parallel Cable
•
Dataproducts Adapter Feature
AS/400: The 6400 is connected to the AS/400 ASCII Workstation Controller
via the following IBM cables, available through your IBM service
representative:
•
20 ft. RS-232
•
40 ft. RS-232
Type
Standard
IEEE 1284 Parallel, Centronics Parallel, RS-232/RS-
422 Serial, Dataproducts Parallel.
Optional
Coax, Twinax, Dataproducts Long Line, Ethernet 10/
100Base-T
Logic Levels
TTL/EIA-232-E, EIA-422-B
Data Format:
ASCII
Compatibility
EIA-232-E, EIA-422-B, PC Parallel, Dataproducts, IEEE 1284,
Twinax, Coax, Ethernet
Transfer
Rates
Up to 200K bytes/sec on parallel interfaces
Up to 19.2 K baud on RS-232 serial interface
Up to 115.2K baud on RS-422 serial interface
Buffer
16 kilobytes on serial interfaces
16 kilobytes on parallel interfaces
Interfaces
Summary of Contents for 6400-i05
Page 1: ...Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers S544 5640 04 ...
Page 2: ......
Page 3: ...S544 5640 04 Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers ...
Page 6: ......
Page 24: ...24 Chapter 1 The IBM 6400 Printer Family ...
Page 102: ...102 Chapter 3 Changing The Power On Configuration ...
Page 248: ...248 Chapter 4 RibbonMinder Menu ...
Page 288: ...288 Chapter 6 Fault Messages ...
Page 304: ...304 Appendix B Printing Speed ...
Page 310: ...310 Appendix C Compatibility and Limitations ...
Page 328: ...328 Appendix D Physical and Logical Unit Types ...
Page 366: ...366 ...
Page 369: ......