setGbicMode
The GBIC mode, when enabled, forces the crossPortTest command or the
spinSilk command to limit its testing to only those ports whose GBICs are detected
as present.
To enable GBIC mode, execute the command as shown in Figure 58.
To disable GBIC mode, execute the command as shown in Figure 59.
spinSilk
Table 36 on page 112 and Table 37 on page 113 show the spinSilk command,
which verifies the intended functional operation of the switch. It sends frames from
the transmitter on each port through the GBIC and external cable, and back to the
receiver on another port at the full hardware speed of 1Gbps. It exercises the entire
path of the switch.
Because the CPU is not comparing data on each frame as with the other two frame
tests, the DIAG-DATA error is never reported during the spinSilk test. However, the
other error messages defined for the crossPortTest test and their corresponding
probable causes and actions are applicable to the spinSilk test.
The state of the GBIC mode affects the operation of the spinSilk test. Executing the
following command before executing the crossPortTest activates the GBIC mode:
switch:admin> setGbicMode 1
When activated, only ports with GBICs installed are included in the spinSilk list of
ports to test. For example, if only ports 0 and 3 have GBICs installed and the GBIC
mode is activated, the spinSilk test only tests ports 0 and 3.
The state of the GBIC mode is saved in flash. It stays activated (even after a restart
or a power-on and power-off cycle) until it is disabled as follows:
sw:admin> setGbicMode 0
Reset GBIC mode before returning the switch to normal operation.
An example mode of operation is to disable the switch, set the GBIC mode to 1,
and execute the spinSilk test . In this example, the testing is limited to all ports that
have GBICs installed and that are cable loopbacked correctly.
Attention:
This command must not be performed on an operational switch.
Before issuing the spinSilk command, disable the switch by using the
switchDisable command.
switch:admin> setGbicMode 1
Figure 58. setGbicMode 1 command example
switch:admin> setGbicMode 0
Figure 59. setGbicMode 0 command example
Appendix B. Diagnostics
111
|
|
|
|
|
Summary of Contents for 2109 - SAN Fibre Channel Switch Model S16
Page 2: ......
Page 3: ...IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide SC26 7352 01 IBM...
Page 12: ...x IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 14: ...xii IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 34: ...18 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 60: ...44 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 84: ...68 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 100: ...84 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 106: ...90 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 132: ...116 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 146: ...130 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 154: ...138 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 160: ...144 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 172: ...156 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 177: ......