on each port back to the receiver on the same port by way of an internal hardware
loopback. It tests the switch circuitry up to the serial output of the ASIC.
The loopback point chosen by the portLoopbackTest depends on what kind of GBIC
module is present. If a GBIC other than an optical SWL or LWL GBIC is present,
the test loops back only at the input (rather than the output) of the serial link.
Copper and unknown GBIC types fall within this category.
The command syntax is.
portLoopbackTest nFrames
Attention:
This command cannot be performed on an operational switch. Before
issuing the portLoopbackTest command, disable the switch by using the
switchDisable command.
If you do not include the nFrames parameter, the loopback test runs continuously
until you press Enter again. If the test does not find an error, there is no output. You
can choose to continue the test, view statistics, or view an error log. Table 35
explains the loopback errors message fields.
While the test is running, all interface module front panel LEDs rapidly flicker green,
indicating that the test is finding no errors and is processing.
Table 35. portLoopbackTest command field descriptions
Field
Description
Diagnostics Status
The title header displays the time the diagShow command was
performed.
port#
The port number.
diags
The current diagnostic status of the port.
Possible values include
OK
,
BAD
.
switch:admin> portLoopback Test
Running Port Loopback Test ....
Diags: (Q)uit,
(C)ontinue,
(S)tats,
(L)og: s
Diagnostics Status:
Sun Jan
1 00:00:00 2000
port#:
0
1
2
3
4
5
6
7
diags:
OK
OK
OK
OK
OK
OK
OK
OK
state:
UP
UP
UP
UP
UP
UP
UP
UP
lm0:
lm1:
lm2
lm3
lm4
lm5
lm6
lm7
4654 frTx
4654 frTx
4654 frTx
4654 frTx
4654 frTx
4654 frTx
4654 frTx
4654 frTx
4654 frRx
4654 frRx
4654 frRx
4654 frRx
4654 frRx
4654 frRx
4654 frRx
4654 frRx
0
0
0
0
0
0
0
0
LLI_errs.
LLI_errs.
LLI_errs.
LLI_errs.
LLI_errs.
LLI_errs.
LLI_errs.
LLI_errs.
Central Memory OK
Total Diag Frames Tx: 38032
Total Diag Frames Rx: 39232
Diags:
(Q)uit,
(C)ontinue,
(S)tats,
(L)og: q
aborted
Figure 55. portLoopbackTest command example
Appendix B. Diagnostics
109
Summary of Contents for 2109 - SAN Fibre Channel Switch Model S16
Page 2: ......
Page 3: ...IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide SC26 7352 01 IBM...
Page 12: ...x IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 14: ...xii IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 34: ...18 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 60: ...44 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 84: ...68 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 100: ...84 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 106: ...90 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 132: ...116 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 146: ...130 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 154: ...138 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 160: ...144 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 172: ...156 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 177: ......