Table 30. centralMemoryTest example (continued)
Example
sw7:admin> centralMemoryTest
Running Central Memory Test ... passed.
Related error messages: DIAG-CMBISTRO, DIAG-CMBISRF, DIAG-LCMTO,
DIAG-LCMRS, DIAG-LCMEM, DIAG-LCMEMTX, DIAG-CMNOBUF,
DIAG-CMERRTYPE, DIAG-CMERRPTN, DIAG-PORTABSENT, DIAG-BADINIT,
DIAG-TIMEOUT.
cmemRetention test
Table 31 shows the cmemRetentionTest command, which is used to verify that
data written into the SRAMs that make up the central memory are retained and that
data bits do not
drop
when read after some amount of delay since the write
operation.
Attention:
This command cannot be executed on an operational switch. Before
using the cmemRetention test command, disable the switch using the
switchDisable command.
cmemRetention test example:
The cmemRetention Test command performs a
data retention test of the central memory SRAMs.
Table 31. cmemRetention test example
Synopsis
cmemRetentionTest [passCount]
Availability
Administrator
Description
Use this command to verify for data retention in the central memory
SRAMs in the ASIC.
Below are possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
Operands
This command has the following operand:
passCount
Specify the number of times to execute this test. The
default value is 1. This operand is optional.
Example
sw7:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.
Related error messages: DIAG-LCMEM, DIAG-LCMRS, DIAG-LCMTO.
cmiTest
Table 32 on page 97 shows the cmiTest command, which verifies that control
messages can be correctly sent from any ASIC to any ASIC. It also tests that the
checksum check is OK.
Attention:
This command cannot be executed on an operational switch. Before
issuing the cmiTest command, disable the switch using the switchDisable
command.
cmiTest example:
The cmiTest command performs a ASIC to ASIC connection
test of the CMI bus
96
IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
||
||
||
|
|
|
|
|
|
||
||
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for 2109 - SAN Fibre Channel Switch Model S16
Page 2: ......
Page 3: ...IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide SC26 7352 01 IBM...
Page 12: ...x IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 14: ...xii IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 34: ...18 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 60: ...44 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 84: ...68 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 100: ...84 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 106: ...90 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 132: ...116 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 146: ...130 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 154: ...138 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 160: ...144 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 172: ...156 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 177: ......