Related error messages: DIAG-MEMORY, DIAG-MEMSZ, DIAG-MEMNULL.
portLoopbackTest
The portLoopbackTest command verifies the intended functional operation of the
switch by sending frames from the transmitter on each port back to the receiver on
the same port using an internal hardware loopback.
Pressing Enter while the portLoopbackTest is selected displays a reminder to take
the switch offline, if it is not offline. If the message is displayed, take the switch
offline.
The portLoopbackTest command is an internal test that continues to run until you
press any button. While the test is running, all GBIC module front-panel LEDs
rapidly flicker green; that indicates that the test is finding no errors and is
processing.
To stop the test, press any button. The panel activates the display shown in
Figure 40.
Related error messages: DIAG-INIT, DIAG-PORTDIED, DIAG-XMIT,
DIAG-TIMEOUT, DIAG-ERRSTAT, DIAG-STATS, DIAG-DATA, DIAG-PORTABSENT.
Port register test
Figure 41 shows the portRegTest command, which checks each register and static
memory that are located on the system board. Registers are set under firmware
control and control the hardware route selection and other internal hardware
functions.
Attention:
This command cannot be performed on an operational switch. Before
issuing the portRegTest command, disable the switch by using the switchDisable
command. Disabling the switch halts all operation on the switch.
This test validates that all registers can be successfully accessed.
Related error messages: DIAG-REGERR, DIAG-REGERR_UNRST,
DIAG-BUS_TIMEOUT.
Push button test
Pressing Enter while the push button test is running activates the display shown in
Figure 42 on page 100.
0x10199a10 len 13091456
ramTest: passed
Figure 39. ramTest
Port Loopback Test: Aborted
Figure 40. portLoopbackTest command example
switch:admin> portRegTest
Running Port Register Test . . . . . .passed.
Figure 41. portRegTest command example
Appendix B. Diagnostics
99
Summary of Contents for 2109 - SAN Fibre Channel Switch Model S16
Page 2: ......
Page 3: ...IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide SC26 7352 01 IBM...
Page 12: ...x IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 14: ...xii IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 34: ...18 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 60: ...44 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 84: ...68 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 100: ...84 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 106: ...90 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 132: ...116 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 146: ...130 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 154: ...138 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 160: ...144 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 172: ...156 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Page 177: ......