Chapter 4 Unit connection / In
stallation and Wiring
4.3 Wiring method
ME0394-1A
4-16
[EtherNet/IP] [PROFINET IO]
Connector name
EtherNet/IP, PROFINET IO cable connector
Remarks
Cable side
Ethernet ANSI/TIA/EIA-568-B Category 5 or higher shielded
8P8C modular plug (RJ45)
To be prepared
by the customer
Controller side Ethernet ANSI/TIA/EIA-568-B Category 5 or higher shielded
8P8C modular jack (RJ45)
Pin No.
Signal name
Description
Compatible wire diameter
1
TD+
Transmit data +
For the Ethernet cable,
use a straight STP cable of
Category 5 or higher.
2
TD-
Transmit data -
3
RD+
Receive data +
4
-
Not used
5
-
Not used
6
RD-
Receive data -
7
-
Not used
8
-
Not used
Controller side
Connector top view
1
8
Ethernet straight cable
Category 5 or higher
Aluminum tape and braided double
cutoff shielded cable recommended
Master unit
Slave device
Switching hub
REC
EtherNet/IP specification
or
REC
PROFINET IO specification