Chapter 4 Unit connection / In
stallation and Wiring
4.2
Unit connection / Installation
ME0394-1A
4-4
4.2.2 Unit connection
In here, describes how to link units in REC system. It is recommended that the unit link is
established before connected to DIN rails.
(1) Turn the operating parts of the connector upper/bottom part towards the panel and position
on the panel end.
(2) The 2 sections circled with a dashed line and the 4 positioning bosses within the square
dotted lines are used as a total of 6 mating sections for positioning 2 units.
(3) When positioning is completed, insert the cable connectors × 2 so that they are firmly
connected.
(4) Turn the operating parts of the connector upper/bottom part towards the rear, rotating firmly
until you feel a click.
Connector bottom part operating part
Connect
Connect
Disconnect
Disconnect
Connector upper part operating part