Chapter 6 Parameter
6.2 Parameter Details
6-3
ME0394-1A
[Auto switch "LS" signal detection range adjustment (Parameter No. 2)]
No.
Name
Unit
Input range
Default initial value setting
2
Auto switch "LS" signal
detection range
adjustment
mm
Actuator Depended
to 9,999.99
0.10
●
Sets the backward complete/forward complete ON trigger range relative to the
backward end/forward end.
●
When the ELECYLINDER enters the detection range, the backward complete or
forward complete signal turns ON.
●
The minimum setting unit is 0.01mm.
The LS signal detection range for
the conditions below is
shown in the figure.
Backward end:
0.00mm
Forward end:
100.00mm
Parameter No.2 : 0.10mm
Caution
●
A value smaller than the minimum resolution cannot be set.
Minimum resolution [mm/p] = ball screw lead [mm/r]
÷
800 [p/r]
Backward end
0.00mm
Forward end
100.00mm
[LS0 detection range]
-0.10 to 0.10mm
[LS1 detection range]
99.90 to 100.10mm
Configuration example