Chapter
7 T
roubleshooting
7.3 Causes and countermeasures for ELECYLINDER alarms
ME0394-1A
7-11
[Warning: Maintenance warning 1]
This is an alert that the target value of the "total travel count" set by the customer has been
reached.
No.
Cause
Countermeasure
1
For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→
For how to grease, refer to the instruction
manual for each ELECYLINDER.
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.
* Refer to “Maintenance Information” in an instruction manual of each ELECYLINDER for how to set
up the maintenance alarms.
[Warning: Maintenance warning 2]
This is an alert that the target value of the "total travel distance" set by the customer has been
reached.
No.
Cause
Countermeasure
1
For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→
For how to grease, refer to the instruction
manual for each ELECYLINDER.
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.
* Refer to “Maintenance Information” in an instruction manual of each ELECYLINDER for how to set
up the maintenance alarms.