Chapter 3 Installation,
iring, Conguration
3.2
Wiring
ME0416-1A
3-6
[Electric wire diameter used for RCON-LC 24V power supply wiring]
For the wires to be connected to the power connector, use the following applicable wires.
Compatible wire
Signal name
Content
Compatible wire diameter
MP
24V
Motor drive power supply
AWG20 ~ 8 (Copper wire)
0V
CP
24V
Control power input
AWG24 ~ 12 (Copper wire)
0V
FG
Frame ground
AWG14 ~ 12 (Copper wire)
* Use cables with their rated temperature on the isolation sheath at 60 C or higher.
The controller current consumption varies depending on the controller model and the motor type
of the actuator to be connected. Refer to RCON System instruction manual "Specification
Section Chapter 2, 2.3 Specifications/ Power supply capacity".
Caution
Using a cable with diameter less than the applicable cable diameter or wiring distance too
long may cause an error due to the voltage drop or may drop the actuator performance.
In such a case, have the output voltage of the power supply adjusted to 24V for the
controller supply voltage.