Chapter 1 RCON-LC System
1.5
Specifications
1-13
ME0416-1A
The specifications regarding the PLC features are as shown below.
Item
Specifications
Programming Language
LD (Ladder Diagram : Ladder Diagram)
Program Memory
32768 step
Max. Control Axis Quantity
16 Axes
Data Retaining Applicable Items
Ladder Program, OM Comment, Label
Comment
Types of
Commands
Basic Commands
25 commands
Application Commands
56 commands
DFC Commands
35 commands
Calculation
Process
Speed
Basic Commands
(LD: Contact)
0.416 s
Basic Commands
(OUT: Output)
0.396 s
Application Commands
(MOV: Transference) 1.916 s
Application Commands (B/: Division)
4.833 s
Input and
Output Points
Input Points
0 to 128 points
Output Points
Remote I/O
Points
CC-Link
CC-Link IE Field
6 to 24 words (1 time 1 station to 4 stations)
Input : 96 to 384 points
Output : 96 to 384 points
DeviceNet
EtherCAT
EtherNet/IP
PROFIBUS-DP
PROFINET IO
1 to 16 words
Input : 16 to 256 points
Output : 16 to 256 points
Device
Memory
Input and
Output
Relays
Input Relay
X000 to X07F 128 points
Output Relay
Y000 to Y07F 128 points
Support
Relays
For General
M0 to M3071 3072 points
For Retaining
LM0 to LM255 256 points
For Axis Control
AM0 to AM4095 4096 points
For System
SM0 to SM127 128 points
Timer
10ms
(0.01 to 327.67 Second)
T0 to T63 64 points
Counter
16-Bit Up
(0 to 32767 counts)
C0 to C63 64 points
Data
Registration
16-Bit for General
D0 to D127 128points
(32 bits in pair use)
16-Bit for System
SD0 to SD63 64points
16-Bit for Joint Indication
IX0 to IX1 2points
Pointer
For JUMP and CALL
Divergence
L0 to L255 256 points
(For JE, JMP, CALL
and CALLP Commands, L0 is initial routine,
L255 is for END Jump)
Constant
Decimal Numbers
16 bits : -32765 to 32767
32 bits : -2.147.483.648
to +2.147.483.647
Hexadecimal Numbers (H)
16 bits : 0 to FFFF
32 bits : 0 to FFFFFFFF
Summary of Contents for RCON-LC
Page 2: ......
Page 18: ...International Standard Compliance Intro 11 ME0416 1A ...
Page 110: ...Chapter 4 PLC Features 4 3 Error Code 4 24 ME0416 1A ...
Page 115: ......
Page 116: ......