Chapter 3 Installation,
iring, Conguration
3.3
Configuration
ME0416-1A
3-18
3. Main Window (After Parameters Read in)
Main Window after Parameters (CC-Link IE Field) Read in
Data of “Configuration setting” and “Occupation information” should be displayed.
Difference from RCON System
[Configuration setting]
•
Minimum axis quantity available to connect is 0
•
Setting of TP port baud rate available
•
Operation mode setting removed as it is to be set in DFC Commands
•
Option unit are supported, but no setting for number of units (because gateway unit can
automatically write in number of connected units)
[Occupation information]
•
Displayed when read out from gateway in connection
(Should not be displayed when file edit)