Chapter pecications for unit
2.1 LC unit
2-5
ME0416-1A
[AUTO/MANU switch]
The status of RUN/STOP in the LC features can be switched over with AUTO/MANU switch.
[LED display]
LED for indicating LC unit status and field network status.
Panel notation Display
color
Status
Description
T RUN
Green
Light ON
Normal internal bus communication
Blinking
Waiting for initialization signal
Orange
Light ON
Bus communication error generated
SYS
Green
Light ON
Gateway normal operation
Orange
Light ON
Gateway alarm triggered
STOP
Red
Light ON
With STOP Signal Input
Light OFF Without STOP Signal Input
MODE
Green
Light ON
AUTO mode ON : PLC RUN Status
Light OFF MANU mode ON : PLC STOP Status
C ERR
Orange
Light ON
Field network error generated
Light OFF Field network operating normally
STATUS 0
Differs with field network
STATUS 1
Differs with field network
The hardware specifications and software specifications in each type of field network should be
the same as RCON System. Refer to RCON System Instruction Manual (ME0384).
Symbol
Description
AUTO
LC: RUN Status
MANU
LC: STOP Status