N700 Operating Instructions and Parts Manual
4. Parameter Code List
26
Name
Indication
Contents
STORE key
STR
The key to store the data setting values.(On changing a set
value, must be pushed or value is lost.)
RUN key
RUN
Run command to start the motor. But this is only valid when
operation command is from the operator. (Be sure that the
operation command display lamp is illuminated)
STOP/RESET key
STOP/RESET This key is used to stop the motor, or reset an alarm.
Volume -
Allows an operator to directly set the motor speed when the
potentiometer is enabled for output frequency setting
method.
(2) Operation
Method
①
keypad navigation map (Method to display monitor mode, basic setting mode, extension
function mode)
Power ON
FUNC
FUNC
FUNC
STR
FUNC
When power is turned off while the basic setting mode or the extension setting mode is
displayed, the display will be different from the above when the power is restored.
It is possible to shift to other extension function modes, monitor modes and basic modes
in [A--, b--, I--, o--, C--, H--, P--] state.
②
Key explanation
[Function key ]
: This key is used to navigate through the lists of parameters
and functions for setting and monitoring parameter values.
If this key is pressed, mode is changed as below
1) Initial value :
- Display of monitor contents set when power
is turned on.
- Display output frequency d001 : 0.00 [Hz]
2) Changing between function mode
- Function mode is changed using the
key and the key.
- display monitor code No.(Display d001)
(ex: 0.00
→
push the key 1 times
→
d001 )
Monitor mode is displayed by pushing
the key once
when display of monitor mode is NO.
- display extension function mode(Display A--)
(ex : A001
→
push the key 1 times
→
A--- )
Except the monitor mode and F-Group.
- extension function mode display in order of
A
↔
b
↔
I
↔
o
↔
C
↔
H
↔
P.