![Hyundai 20BC-7 Service Manual Download Page 216](http://html.mh-extra.com/html/hyundai/20bc-7/20bc-7_service-manual_2196423216.webp)
7-64
After changing SCR module or PCB (SE-
5000SN), the charger's normal operation
should be checked.
Â
Â
Checking order
Separate the charger and battery
connector.
Separate lower cover in the front of the
charger.
Check the AV input voltage used from the
input switch terminal in the lower left side
of the inside of the charger.
Checking method between terminals.
Input voltage setting value
Ą
220V 380V
- Between terminals No. 2 - No. 4 220V 380V
- Between terminals No. 2 - No. 6 220V 380V
- Between terminals No. 4 - No. 6 220V 380V
Above cases are under normal
operations.
When installing charger for the first time
or moving its location, check and make
it sure if the voltage is appropriately
connected.
Refer to No. 2 of the charger installation
method for the terminal connection
method.
- In case of 220V : (2), (4), (6), (8)
- In case of 380V : (1), (3), (5), (7)
It should be connected to the terminal.
(1)
(2)
(3)
ö
ö
BR7BAT05
BR7BAT06
220V
380V
HOW TO CHECK THE CHARGER'S NORMAL OPERATION
4)