PUMP CONTROLLER
Using the config menu of the programming console, the user can configure the following functions.
Submenu "SET OPTIONS"
Hour counter
- RUNNING : The counter registers travel time only.
- KEY ON : The counter registers when the "key" switch is closed.
Set temperature
- DIGITAL : A digital (ON/OFF) motor thermal sensor is connected to A25 input.
- ANALOG : An analog motor thermal sensor is connected A25 (the curve can be customized on
a customer request).
- NONE : No motor thermal sensor switch is connected.
Digital lift
- OFF : The lift sensor includes a lift switch and an analogue lift sensor. Lift speed can be
controlled proportionally with lever position.
- ON : The lift sensor includes a lift switch only. Lift speed cannot be controlled proportionally.