Description of ALARMS menu
The microprocessor in the controller records the last five alarms that have occurred. Items
remembered relative to each alarm are: the code of the alarm, the number of times the particular
Alarm occurred, the hour meter count, and the inverter temperature.
This function permits a deeper diagnosis of problems as the recent history can now be accessed.
Flow chart showing how to use the ALARMS function via the digital console.
(3)
Opening Zapi display.
Press ENTER to go into the general menu.
The display will show:
Press ROLL UP or ROLL DOWN button until
PARAMETER CHANGE. appear on the display.
The display shows:
Press ENTER to go into the ALARMS function.
The display will show the most recent alarm.
Each press of the ROLL UP button brings up
following alarms. Pressing ROLL DOWN returns
to the most recent.
If an alarm has not occurred, the display will
show: ALARM NULL.
When you have finished looking at the alarms,
press OUT to exit the ALARMS menu.
The display will ask "CLEAR LOGBOOK?".
Press ENTER for yes, or OUT for NO.
Press OUT to return to the opening Zapi display.