Pump controller
The most important input or output signals can be measured in real time using the TESTER
function of the console. The console acts as a multimeter able to read voltage, current and
temperature. The following definition listing shows the relative measurements :
Motor voltage
This is the voltage supplied to the motor by the inverter; it is expressed as a percentage of the full
voltage (which depends of the battery voltage).
Frequency
This is the frequency of the voltage and current supplied to the motor.
Encoder
This is the speed of the motor, expressed in the same unit of the frequency; this information
comes from the speed sensor.
Slip value
This is the difference of speed between the rotating field and the shaft of the motor, expressed in
the same unit of the frequency.
Current rms
Root Mean Square value of the motor current.
Temperature
The temperature measured on the aluminum heat sink holding the MOSFET devices.
Motor temperature
This is the temperature of the motor; if the option is programmed "None" it shows 0
Á
.
L
L
ifting switch:
Status of the lifting switch.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Descent switch:
Status of the lowering speed switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Tilt up switch:
Status of the tilt up switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Tilt down switch:
Status of the tilt down switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Shift lft switch:
Status of the shift left speed switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Shift rgt switch:
Status of the shift right speed switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.