![Hyundai 20BC-7 Service Manual Download Page 210](http://html.mh-extra.com/html/hyundai/20bc-7/20bc-7_service-manual_2196423210.webp)
7-58
Code
Alarm string
Description
Condition that has to occur
to come out from
alarm status
253
13
61
65
66
250
78
79
80
249
251
247
250
AUX OUTPUT
KO
EEPROM KO
HIGH
TEMPERATU-
RE
MOTOR
TEMPERATU-
RE
BATTERY
LOW
HANDBRAKE
VACC NOT
OK
INCORRECT
START
F
BACKWARD
THERMIC
SENSOR KO
WAITING
FOR NODE
NO CAN
MESSAGE #X
CANBUS KO
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Alarm: EB coil driver
shorted or open
Warning: Eeprom
fault, controller will use
default parameters
Warning: Master or
Slave or both tempera
-ture higher than 75
Á
C
Warning: Master or
Slave or both motors
temperature high
Warning: Battery ch-
arge level below 10%
Warning: Handbrake
microswitch is open
and a travel request is
active
Warning: Acc.signal
(CPOT)voltage higher
than VACC MIN +1V
while the traction en-
able switch is open
Warning: Wrong trac-
tion request sequence
Warning: Forward and
reverse inputs are
both active
Warning: Master or
slave temp. sensor is
out of range
Warning: Master
ʂ
C
signals that slave or
pump
ʂ
C is in alarm
status
Alarm:
Master/Slave has lost
Can communication
with #X
Alarm:
Inverter has lost Can
communication
If the alarm is present in
Init status, remove the
alarm cause
If the alarm has occurred in
standby or running mode, it
is necessary to remove
alarm cause and to
activate traction request
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove Warning cause
To remove warning cause
To remove Alarm cause
To remove Alarm cause
Â
Â
Traction
Pump