7-37
Aux in switch:
Status of the aux in switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Aux out switch:
Status of the aux out switch of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Hydro speed req.:
Status of the hydro speed request of the pump.
- ON / +VB = Active entry of closed switch.
- OFF / GND = Non active entry of open switch.
Lift/lower req.:
Level of the lift and lower analogue signal. The voltage is shown on the left hand side of the
display and the value in percentage on the right hand side.
Tilt request:
Level of the tilt analogue signal. The voltage is shown on the left hand side of the display and the
value in percentage on the right hand side.
Shift request:
Level of the shift analogue signal. The voltage is shown on the left hand side of the display and
the value in percentage on the right hand side.
Aux request:
Level of the auxiliary analogue signal. The voltage is shown on the left hand side of the display
and the value in percentage on the right hand side.
Cutback switch:
Status of the speed reduction switch.
- ON / GND = Active entry of open switch.
- OFF / +VB = Non active entry of closed switch.
Voltage booster:
This is the booster of the voltage supplied to the motor in load condition; it is expressed in a
percentage of the full voltage.
Battery voltage:
Level of battery voltage measured at the input to the key switch.
⯾
⯿
⬼
⬽
⬾
⬿
⭀
⭁
⭂
⭃