5 | Setting up/assembling/commissioning
HYDAC FILTER SYSTEMS GMBH
44 / 124
BeWa CTU1x3x-CTU1x4x 4093420f en-us web
5.2 Making the electrical connections
The extraction unit is delivered ready for connection with a power
plug.
1. Before plugging in the power plug, compare the voltage in-
formation provided on the name plate of the extraction unit
with the available voltage from the power supply.
2. Plug the power plug only into a power outlet with a ground
connection.
O
The extraction unit is electrically connected to the supply net-
work.
5.2.1 Checking the terminal strip in the switch box
While transporting the extraction unit, it is possible that the resis-
tors come loose in the X2 terminal strip.
DANGER
Danger - Due to dangerous electrical voltage
Danger of fatal injury
u
Work on the electric supply may only be carried out by a prop-
erly trained, certified electrician.
u
Pull out the power plug before performing any work.
Prior to commissioning the unit, check the resistors R1 / R2 / R3 /
R4 on the X2 terminal strip according to the following figure:
Fig. 14:
Resistors in the X2 terminal strip
R1 500 Ω
R2 500 Ω
R3 2.8 kΩ
R4 2.8 kΩ
1
2
3
4
5
6
7
8
9
A