FluidAqua Mobil - FAM 10/15-P
Performing maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 64 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Cleaning the suction strainer
NOTICE
Operation without a suction screen
The pump will be destroyed
►
The FCU may not be operated without the suction strainer.
►
Clean the suction screen regularly.
To protect the pump from coarse contamination particles and other foreign bodies, a
dirt trap with a strainer insert is fitted at the pump inlet.
Clean the suction screen at regular intervals.
To disassembly/install the suction screen, proceed as follows:
1. Unscrew the screw plug (1)
counterclockwise with an open-jaw
wrench.
2. Remove strainer insert (3) and
clean it.
3. Clean the strainer insert, flush it out
and then blow-flush it using
compressed air.
3. Check strainer insert (3) and the
seal ring (2) on the screw plug for
damage and replace if necessary.
4. Insert the strainer insert (3).
5. Manually screw in the screw plug
(1) clockwise.
Tighten the screw plug (1) with a
open-jaw wrench.
6. Check the suction strainer fitting for
leaks after commissioning.
1
2