FluidAqua Mobil - FAM 10/15-P
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 48 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Float switch
Step
Description
Malfunction:
"Float switch"
1.
Empty oil pan
2.
Press RESET key
3. Start
FAM
4.
Carry out leakage check, remedy leakages
5.
Malfunction reappears after ~ 2 seconds?
->a. Yes
-> proceed to Step 7.
6.
->b. No
-> proceed to Step 8.
7.
Check float switch and supply lines
8.
The failure is repaired.