FluidAqua Mobil - FAM 10/15-P
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 53 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Inlet (IN) clogged
Step
Description
1. Malfunction:
"Inlet clogged"
2.
Cause: Medium cannot make its way into the vacuum chamber
3.
Check locking features in the suction line. Open if blocked.
Check suction strainer and clean if necessary
4.
To reset the failure, press the RESET key
5.
Malfunction reappears after ~ 4 minutes?
->a. Yes
-> proceed to Step 7.
6.
->b. No
-> proceed to Step 8.
7.
Check the following points:
-
Check the suction pipe for cross-section constriction
-
Check the functioning of vacuum pump in manual mode
-
Check the position of the shut-off device in the suction line
8.
The failure is repaired.