FluidAqua Mobil - FAM 10/15-P
Performing maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 57 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Maintenance Intervals
The inspection and maintenance work listed here are necessary conditions for
ensuring both long service life and error-free operation of the unit.
In addition, you will find further information in the operating manuals published by
the manufacturers of the components which are supplied with the unit.
See page
24 hours /
daily
500 hours /
monthly
3000 hours /
every six months
6000 hours /
annually
FAM
Visual check for leakage
-
X
Check threaded joints for fixed seat,
tightening them as needed.
-
X
Inspection of the measurement
technics /
Pressure sensor in the vacuum column
/
Differential pressure manometer at the
fluid filter /
AquaSensor at the IN port /
ETS at the vacuum column (optional)
-
X
Fault indicator lamp function
X
Change the air filter
(if this has not been required earlier)
X
Clean suction filter /
X
Rotary Valve Pump Vacuum Pump
Check oil level
-
X
Replace oil, oil filter and air de-oiling
element
X
1)
Cleaning and inspecting the ventilator
hood
X
Change the active carbon filter
cartridge
X
Emptying/filling pump
Cleaning and inspecting the ventilator
hood
-
X