FluidAqua Mobil - FAM 10/15-P
Starting up the FAM
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 38 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Draining the filterhousing
WARNING
Hot fluid
Risk of burns
►
Note that hot fluid may exit during draining.
The fluid filter is to be bled through the air-vent plug until fluid emerges. Using an
Allen wrench carefully open the air-vent plug in the cover.
Shut off FAM
Press the
key. Now the system starts the run-down phase:
FluidAqua operating
Run-down
1. The inlet valve closes
2. The vacuum pump is switched off
3. The filter-pump unit runs until the vacuum chamber is emptied.
Wait until the message appears on the display. Now move the main switch to the
position "0". The system is now switched off.
Ready for operation
--> Press start