FluidAqua Mobil - FAM 10/15-P
Hydraulic diagram
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 27 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Item Designation
6
Float switch
7
Emptying pump
8
3/2-directional control valve
9
Rotary Vane Vacuum Pump
10
Vacuum pump drain
11
Filling pump (OLF 5)
12
Fluid filter for separating solid particles
13
Vacuum chamber drain
14
Vacuum chamber level sensor
15
Suction strainer
16
Vacuum chamber
17
Heater mounted in vacuum chamber (Option)
18
Air filter and dryer
19
control cabinet with control panel consisting of:
- main switch
- alarm signal lamp
- control panel with display
- component diagram
20
Regulating valve to regulate the necessary vacuum in the vacuum chamber
21
Vacuum gauge
22
Inlet (INLET)
23
Outlet (OUTLET)
24
Motor-pump assembly for the ContaminationSensor
25
ContaminationSensor CS 2000
26
AquaSensor AS2000
27
Active carbon filter
28
Condensate separator
29
Check valve
30
Venting valve
31