FluidAqua Mobil - FAM 10/15-P
FAM Set-up and Connection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 36 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
Checking the settings on the heater (optional)
If necessary the desired fluid temperature can now be set.
For this, the upper cover of the heater must be opened with appropriate equipment
and the desired operating temperature set. (The working temperature is preset to
55°C; if 80°C is exceeded, then the safety thermostat will shut the device off.)
(A)
Fluid temperature
55°C
(B)
Safety thermostat
80°C
Filling the condensate separator
Prior to start up, fill the condensate separator with 1.5 liters of vacuum pump oil
(VE101), as described on page 63.