FluidAqua Mobil - FAM 10/15-P
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 49 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
E/V/R pump motor protection
Step
Description
Malfunction:
"E/F/V pump motor protection"
1.
Switch off FAM at the main switch and pull out mains plug
2
Open the switch cabinet door, switch the motor protection switch
and/or fuse back on "I" that has tripped and check the setting of the
motor protection switch and/or the voltage capacity of the fuse in
accordance with the motor type plate and/or the heater type plate.
->a. The fault recurs
-> proceed to Step 4.
3.
->b. The failure does not recur
-> proceed to Step 8.
4.
Measure the current consumption of the engines whose motor
protection switch
or fuse has tripped.
5.
Close switch cabinet door, main switch to "On", start FAM
->a. The fault recurs
-> proceed to Step 7.
6.
->b. The failure does not recur
-> proceed to Step 9.
7.
Check the operating viscosity of the medium (only for motor protection
switch),
perform maintenance work on the vacuum pump
8.
The failure is repaired.