FluidAqua Mobil - FAM 10/15-P
Performing maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 63 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
To replace the filter element on the condensate separator, proceed as follows:
1.
Open the profile clamp and remove the base in a downwards direction.
The base contains ~ 1.5 liters of vacuum pump oil (VE101).
2.
Remove the used filter element (2).
3.
Insert the new filter element (2).
4.
Check the two seals (3) for damage, and replace them if necessary.
5.
Check the fill level on the inspection glass. If necessary, fill up the condensate
separator, as described on page 63.
6.
Insert the base upwards into the upper part of the condensate separator and
close the profile clamp.
Checking the fill level on the condensate separator
Check the fill level of the vacuum pump oil (VE101) on the inspection glass of the
condensate separator.
During downtime (i.e. when the FAM is not in operation), the fill level must be in the
middle of the inspection glass.
If necessary, fill up the condensate separator, as described on page 63.
Filling the condensate separator
To fill up the condensate separator, proceed as follows:
1.
Open the profile clamp and remove the base in a downwards direction.
The base contains ~ 1.5 liters of vacuum pump oil (VE101).
2.
Pour new vacuum pump oil (VE101) into the base via the tube.
3.
Check the fill level. At the very least, this should be in the middle of the
inspection glass.
4.
Insert the base upwards into the upper part of the condensate separator and
close the profile clamp.