FluidAqua Mobil - FAM 10/15-P
Performing maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 58 / 80
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
2011-01-19
See page
24 hours /
daily
500 hours /
monthly
3000 hours /
every six months
6000 hours /
annually
Fluid filter (OLF 5)
Change the filter element
(If this has not been required earlier)
X
Condensate separator
Check the fill level on the condensate
separator
X
Change the filter element on the
condensate separator
X
Electrics
Check cable conduits for damage,
replacing as necessary
-
X
Measure the engine power
consumption of all engines and
compare the values with the type label
-
X
Checking the AquaSensor
-
X
Perform electrical safety inspection in
accordance with DIN VDE 0702 and/or
corresponding national regulation.
-
X
Measure power consumption of the
heater and compare values with type
label (applies only to versions with
integrated heater)
-
X
Function test
Check and clean the level sensor in
the vacuum column.
X
Float switch oil pan - malfunction
message and E-STOP function
X
1)
The first oil change must take place after 100 operating hours.
Completely replace all of the hoses after 5 years.
The pictures and illustrations in the descriptions are examples. They do not
represent all of the different product variants.